Poor lubrication practices are a leading cause of bearing failure. LUBEChecker is an ultrasound solution focused on optimizing grease replenishment. It is the perfect companion for performing lubrication on condition based intervals.
LUBEChecker is so easy to use. Simply open the box, connect it to your grease gun, and hear the difference. Its vibrant color display offers repeatable, accurate, digital measurements that guide you to a precision result every time.
Failed bearings and excessive grease consumption gnaw away at your bottom line. LUBEChecker is the affordable solution. Built with SDT quality, it’s offered at a price that makes you want to Hear More.
Technical Details:
General | |
Function | Ultrasound measurement device |
Display | 160×128 pixel Color OLED |
Keyboard | 5 function keys |
Typical measurement range | -6 to 99.9 dBμV (reference 0 dB = 1 μV) |
Resolution | 0.1 digits |
Measurement bandwidth | 35 to 42 kHz |
Signal amplification | +30 (built-in sensor gain) dB to +102 dB by step of 6 dB |
RMS period time | 250 milliseconds (main screen) / 3 sec (bar graph) |
Sampling frequency | 64 kHz |
ADC Resolution | 12 bit |
Minimum sensitivity | -31dB (@40 kHz, 0 dB-1 V/µbar) |
Environmental | |
Operating temperature range | -10 to +50 °C |14 to 122°F |
IP rating | IP42 |
Standards | EN 61326-1:2013, EN 55011:2016 + A1:2017, EN 61000-4-2:2009, EN 61000-4-3:2006 + A1:2008 + IS1:2009 +A2:2010 |
Mechanical | |
Housing material | ABS |
Dimensions housing | 158 x 59 x 38,5 mm |6.22” x 2.32” x 1.51” |
Flexible rod length (Removable sensor) | 445 mm |17.51” |
Weight | 350g | 12.35 oz |
Battery/Utility connector | USB Mini-B 5-pin |
Power | |
Battery | 2 AA batteries |
Autonomy | 7 hours |
Audio | |
Operable with | SDT provided head set only |
Maximum audio output (protection) | +83dB SPL with SDT headset |
Headset | 25dB NRR Peltor HQ headset |
Other | |
Warranty | Lifetime |