You are currently viewing CUMMINS DG SETS 380KVA
CUMMINS 380KVA DG SETS

CUMMINS DG SETS 380KVA

CUMMINS DG SETS 380KVA

Cummins dg sets understands how essential uninterrupted power is for all – home, business and commercial. Powered by the technologically advanced power generation solutions starting from 7.5kVA to 3750kVA, our product range is geared to take on the most challenging applications. In fact, Cummins dg sets in Bhubaneswar.

Similarly, Our power solutions are built in to deliver consistent performance across all industry segments, ensuring that you always stay ahead of the rest. In fact, We promise quality products and exceptional customer support.

Established in 1904, In fact, Cummins dg sets Technologies manufactures alternators under the renowned NEWAGE®, STAMFORD® and AvK® brands setting the industry standard, with a range extending from 7.5 to 11,200kVA, suitable for all generator set configurations. Although our products are used in a variety of applications, In fact, the common factor is that Cummins dg sets Technologies work to a single standard for all products and services no matter where you are in the world.

Jakson takes pride in being the forerunner of the Indian diesel generator industry and has continued its legacy and excellence over four decades with utmost integrity, innovation, customer centricity, teamwork and care, which are also the company’s core values.We are the pioneers in the diesel generator industry, having introduced the concept of silent gensets in India. Together with Cummins, Jakson is a market leader across the low, mid and high-capacity diesel generator market in India.

Similarly, As the business grew, the company expanded its manufacturing footprint by establishing new plants in Kathua and Daman. In fact,The Daman plant was one of the most advanced diesel genset manufacturing units in the country during the early 2000s. To keep up with the growing demand for its silent gensets, the company consolidated its Cummins DG Sets manufacturing facilities and today has state-of-the-art manufacturing plants located in Kathua and Kalsar.

Kalsar Plant

Similarly, Jakson manufacturing plant in Kalsar, Gujarat was established in the year 2011 and serves as an integrated plant for manufacturing acoustic enclosures and DG Sets. In fact, The plant has an installed capacity of 11000 generators and 35,000 enclosures annually. It has a total manufacturing space of 3.5 lakh square feet and is spread across 17 acres.

Kathua Plant

Similarly, Jakson has two manufacturing plants in Kathua, Jammu & Kashmir. These integrated plants are amongst the largest manufacturing facilities in the region and offer employment to hundreds of local youths, leading to considerable economic growth and prosperity in the region. In fact, The unit is equipped with state-of-the-art infrastructure to cater to the increasing domestic requirement of DG Sets. The plant is built over 7 acres and has an annual capacity of 2000 Diesel Generators.

CUMMINS 380KVA DG SETS TECHNICAL SPECIFICATIONS

Diesel Generator Set
QSN14 Series
365-400 kVA, 292-320 kWe Prime
Latest Technology Product with
Global Cummins® Platform
ƒƒThe Cummins® QSN14 series heavy-duty engine
and world class Stamford alternator powered diesel
generator set
ƒƒClass defining Quantum engine technology with fully
integrated subsystems
ƒƒAdvanced in-cylinder technology to meet latest
emission norms without any after-treatment device
ƒƒSmart aesthetic and superior finish
ƒƒCompact in size with optimum power to weight ratio
Environment Friendly Power
ƒƒClass defining technology engine is designed to meet
stringent exhaust emission tests as per revised MoEF
norms, thus offering environment friendly power.
ƒƒThe Cummins® diesel generator sets are available with
the lowest noise levels in its range
Lowest Operating Cost and
Comprehensive Warranty
ƒƒHighly reliable and durable product
ƒƒAll elements are designed to work together to
maximize efficiency even at part loads, offering the
advantage of lowest operating costs.
ƒƒ500 Hours / 1 year service interval
ƒƒIndustry acknowledged best-in-class comprehensive
warranty on the entire package including rubber
components
Single Source Power Assurance
ƒƒAll the major components – the engine, alternator,
control system and canopy are designed,
manufactured and tested by Cummins India.
ƒƒBest and largest customer support network in India,
capable of providing round-the-clock service and
spares support
ƒƒAll these things put together, Cummins® offers you
SINGLE SOURCE POWER ASSURANCE
S p e c i f i c a t i o n S h e e t
Engine
ƒƒ
Cummins® QSN14 series, 6 cylinder, In-line 4 stroke,radiator cooled engine
ƒƒ
Well designed air handling system with
——
Dry type, Replaceable paper element air cleaner withrestriction indicator
——
Air to air aftercooling
——
Optimised Turbocharger for increased altitudecapabilities
ƒƒ
Best in class fuel economy with
——
CELECT fuel system with A1 class electronic governing
——
Dual fuel filter system: Pre filter including waterseparator and Water In Fuel (WIF) sensor and main filter
ƒƒ
Electrical lift pump for faster response
ƒƒ
Standard integral set-mounted radiator system, designedand tested for 50°C ambient temperature
ƒƒ
Full flow spin on lube oil filter
ƒƒ
Plate type lube oil cooler
ƒƒ
First fill of lube oil and coolant
ƒƒ
Electrical starter motor with soft start engagement feature
ƒƒ
Battery charging alternator
ƒƒ
2 x 12 V DC batteries
Alternator
ƒƒ
Stamford HC alternator frames from Cummins GeneartorTechnologies
ƒƒ
Brushless type, Screen protected, Revolving field, Selfexcited alternator conforming to IS/IEC 60034-1
ƒƒ
3 Phase reconnectable winding with 12 terminals broughtout for connection
ƒƒ
Better motor starting capability
ƒƒ
Best in class efficiency
ƒƒ
Compact design with sealed bearings for longer life andlesser maintenance
ƒƒ
Impregnation on all wound components for bettermechanical strength
Control Panel
Control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish.The control panel consists of the following parts:
ƒƒ
PowerCommand® 1.2 controller
ƒƒ
Aluminum bus bars with suitable capacity with incoming/outgoing terminals
ƒƒ
Indicating lamps for ‘Load ON’ and ‘Set Running’
ƒƒ
Instrument fuses duly wired and ferruled
ƒƒ
MCCB of suitable rating with overload and short circuitprotections
PowerCommand® 1.2 features
The PowerCommand® control system is a microprocessor-based generator set monitoring, metering and control system with LCD display designed to meet the demands of today’s engine driven generator sets
ƒƒ
Intuitive operator interface which includes LED backlit LCDdisplay with tactile feel soft-switches and generator setstatus LED lamps
ƒƒ
Digital AVR for shunt or PMG excitation with torquematching.
ƒƒ
Digital electronic governing with temperature compensationand smart starting.
ƒƒ
SAE J1939 interface to Full Authority Electronic (FAE)engines.
ƒƒ
Remote start-stop
ƒƒ
Engine metering: Oil pressure, Coolant temperature, Batteryvoltage, Engine speed
ƒƒ
AC Alternator metering: L-L Voltage and L-N Voltage,Current (1 and 3 phase), Volt-Amperes (phase and total) andFrequency.
ƒƒ
Engine protection: Low lube oil pressure, High/Low coolanttemperature, Over speed, Battery Over/Under/Weak Volts,Fail to crank/start, Sensor failure.
ƒƒ
AC Alternator protection: Over/Under voltage, Over/Underfrequency, Over current, Short circuit and Loss of ACsensing.
ƒƒ
Data logging: Engine hours, Control hours, Engine startsand upto 10 recent fault codes
ƒƒ
Configurable glow plug control
ƒƒ
Configurable cycle cranking
ƒƒ
12 and 24 Volt DC operation
ƒƒ
Sleep mode
ƒƒ
Programmable I/Os (4 inputs and 2 outputs), expandablewith AUX101/102 modules
ƒƒ
Modbus interface (RS485 RTU)
ƒƒ
InPower compatible (PC based service tool)
ƒƒ
Certifications – meets the requirement of relevant UL, NFPA,ISO, IEC, Mil Std., CE and CSA standards
Silencer
ƒƒ
Hospital grade silencer suitably optimized to meet stringentnoise emission standards laid down by MoEF / CPCB
Mounting Arrangement
ƒƒ
Engine and alternator are mounted on a common MSfabricated base frame with AVM pads.

Cummins dg sets

Base frame with integral fuel tank is provided with drainplug, air vent, inlet and outlet connection, level indicator andprovision for cleaning
Optional
ƒƒ
Engine : Coolant heater, Heat exchanger No Cool
ƒƒ
Alternator: PMG
ƒƒ
Control Panel:
——
PC3.3
——
Bargraph For PC3.3 Panel with kW, Power factor,Frequency,Current, Voltage
——
Remote HMI
Diesel Generator Set QSN14 Series
Specification Sheet
Acoustic Enclosure
ƒƒ
Specially designed to meet stringent MoEF/ CPCB norms of75 dBA @ 1mtr at 75% load under free field conditions
ƒƒ
The acoustic enclosure is made of CRCA sheets in munselgreen shade and a structural/ sheet metal base framepainted in black.
ƒƒ
High quality noise absorbant and fire-retardant gradeacoustic insulation material (Rockwool) complying to IS8183
ƒƒ
Air inlet louvers specially designed to operate at rated load
Technical Data
Generator set specification
Model
C365D5P
C400D5P
Duty
Prime
Prime
Power Rating kVA / kWe
365/292
400/320
No. of Phases
3
3
Output Voltage and Frequency (V and Hz)
415 V, 50 Hz
415 V, 50 Hz
Power Factor
0.8 (lagging)
0.8 (lagging)
Current (A)
508
556
RPM
1500
1500
Engine Specification
Make
Cummins®
Cummins®
Model
QSN14-G1
QSN14-G2
MoEF Certified Power (bhp)
448
487
Required Power for Rated kVA (bhp)
440
475
Cooling
Liquid Cooled (EG Compleat 50:50)
Liquid Cooled (EG Compleat 50:50)
Aspiration
Turbocharged, Charge Air cooled
Turbocharged, Charge Air cooled
No. of cylinders
6, In-line
6, In-line
Bore (mm) x Stroke (mm)
140 x 152
140 x 152
Compression ratio
16.5: 1
16.5: 1
Displacement (litre)
14
14
Fuel
High Speed Diesel
High Speed Diesel
Fuel consumption @75% load with radiator and fan* (litre/hr)
61.05
67.85
Fuel consumption @100% load with radiator and fan* (litre/hr)
77.69
85.65
Performance class of generator set
ISO 8528-5 G2
ISO 8528-5 G2
Starting system
24 V DC Electrical
24 V DC Electrical
Lube oil specification
CI4+ 15W40
CI4+ 15W40
Lube oil sump capacity, High-Low level (litre)
36-28.4
36-28.4
Total lubrication system capacity (litre)
38.6
38.6
Lube oil consumption @ full load** (litre/hr)
0.08
0.09
Total coolant capacity (litre)
51
51
Exhaust pipe size (inch)
6
6
Total wet weight (Engine+Radiator)## (kg)
1706
1706
Length x Width x Height (Engine) (mm)
1502 x 888 x 1219
1502 x 888 x 1219
Mean Piston speed (m/s)
7.5
7.5
Combustion air intake @100% load (±5%) (cfm)
954
1024
Exhaust Temperature (°C)
475
491
Alternator Specification
Make
Stamford (CGT)
Alternator frame
HCI444F
Enclosure
IP23
Voltage regulation (Max.)
±1%
Class of Insulation
H Class
Winding Pitch
2/3
Stator Winding
Double layer lap
Rotor
Dynamically Balanced
Waveform distortion/ Total Harmonic Distortion
No load < 1.5 %, Non distorting balanced linear load < 5 %
Maximum Unbalanced Load across phases#
less than or equal to 25%
Telephonic Harmonic factor
< 2%
Stamford (CGT)HCI444FIP23±1%H Class2/3 Double layer lapDynamically BalancedNo load < 1.5 %, Non distorting balanced linear load < 5 %less than or equal to 25%< 2%
ƒƒ
Base lifting for easy handling at customer site
ƒƒ
Designed to have optimum serviceability
ƒƒ
Made on special purpose CNC machines for consistency inquality and workmanship
ƒƒ
11 tank pretreatment process and UV resistant powdercoating of all parts to withstand extreme environment
ƒƒ
Use of special hardware for longer life
ƒƒ
Flush styling – no projections
ƒƒ
Fluid drains for lube oil and fuel
ƒƒ
Similarly, Fuel filling arrangement inside the enclosure
* Fuel consumption data is based on diesel having specific gravity of 0.85 and conforming to IS:1460. In fact, Fuel consumption tolerance is +5%
# With the condition that none of the phases exceeds its rated current
Diesel Generator Set QSN14 Series
Specification Sheet

Leave a Reply